Fence posts and panels
- For fence posts, fill a max. 4 rows of building blocks at once with moist C 16/20 concrete of a soft consistence.
- The inserted concrete (C 16/20) shall be compacted, e.g., with a steel bar.
- The recommended axial spacing between posts is 280-320 cm.
- Post reinforcement is assessed case by case, notably considering the following:
- height and axial spacing between posts,
- whether gates are hinged on posts,
- wind load,
- weight of fence bays,
- fence panel segmentation.
- For standard loads, reinforce with 4× V10.
- The rebars are embedded in the foundations.
- Clips for dividing the reinforcement 1× E6 (at approx. 20 cm) are inserted in the horizontal joints of posts.
- Fence bay brackets are inserted in the horizontal joints of posts.
- The post and foundation wall height is variable.